Modules Programming Guide - 5
EVO641/EVO641R V1.08
32-Character Blue LCD Keypad Module
The keypad’s serial number can be found on the keypad’s PC board. The keypad’s serial number can also be
viewed by pressing and holding the [0] key, entering the [
INSTALLER CODE] and then entering section [000].
U = Default setting
† Section/option is only available with 57
‡ Section/option is only available with EVO641
Section [001] Keypad Partition Assignment
Options OFF ON
[1]
Partition 1
N Disabled U Enabled
[2]
Partition 2
N Disabled U Enabled
[3]
Partition 3
N Disabled U Enabled
[4]
Partition 4
N Disabled U Enabled
[5]
Partition 5
(EVO192 only) N Disabled U Enabled
[6]
Partition 6
(EVO192 only) N Disabled U Enabled
[7]
Partition 7
(EVO192 only) N Disabled U Enabled
[8]
Partition 8
(EVO192 only) N Disabled U Enabled
Section [002]
Assigning Doors to Partitions †
Options OFF ON
[1]
Door Assigned to Partition 1
N Disabled U Enabled
[2]
Door Assigned to Partition 2
U Disabled NEnabled
[3]
Door Assigned to Partition 3
U Disabled NEnabled
[4]
Door Assigned to Partition 4
U Disabled NEnabled
[5]
Door Assigned to Partition 5
(EVO192 only) U Disabled NEnabled
[6]
Door Assigned to Partition 6
(EVO192 only) U Disabled NEnabled
[7]
Door Assigned to Partition 7
(EVO192 only) U Disabled NEnabled
[8]
Door Assigned to Partition 8
(EVO192 only) U Disabled NEnabled
Section [003]
General Options 1
Options OFF ON
[1] Display code entry U Disabled N Enabled
[2] Display exit delay U Disabled N Enabled
[3] Display entry delay U Disabled N Enabled
[4 Confidential Mode (not for UL installations) U Disabled N Enabled
[5] To exit Confidential Mode U
Enter code
N
Press Button
[6] & [7] Future Use N N/A N N/A
[8] Time display option U
yy/mm/dd
N dd/mm/yy
Section [004]
General Options 2
Options OFF ON
[1] Muting U Disabled N Enabled
[2] Exit Delay Beep N Disabled U Enabled
[3]
Door Left Open Pre-Alarm
†
N Disabled U Enabled
[4] Chime on Zone Closure U Disabled N Enabled
[5]
Door Left Open Alarm Feedback
†
N Silent U Audible
[6] Door Left Open Alarm Follows † U Alarm restore N Beep Timer
[7]
Door Forced Alarm
†
N Silent U Audible
[8]
Door Forced Alarm
†
U Alarm restore N Beep Timer