Modules Programming Guide - 3
DNE-K07 V1.4
Grafica Graphic LCD Keypad Module
Grafica Keypads can be used with DGP-848 and DGP-NE96 V1.3 or higher control panels and Digiplex EVO
series control panels. Grafica will not function with DGP-48 control panels.
The keypad’s serial number can be found on the keypad’s PC board. The keypad’s serial number can also be viewed by pressing and
holding the [0] key, entering the [
INSTALLER CODE] and then entering section [000].
U = Default setting
Section [001] Keypad Partition Assignment
Options OFF ON
[1] Partition 1 N Disabled U Enabled
[2] Partition 2 N Disabled U Enabled
[3] Partition 3 N Disabled U Enabled
[4] Partition 4 N Disabled U Enabled
[5] Partition 5 (EVO 192 only) N Disabled U Enabled
[6] Partition 6 (EVO 192 only) N Disabled U Enabled
[7] Partition 7 (EVO 192 only) N Disabled U Enabled
[8] Partition 8 (EVO 192 only) N Disabled U Enabled
Section [002] System Options
Options OFF ON
[1] Display Code Entry U Disabled N Enabled
[2] Display Exit Delay N Disabled U Enabled
[3] Display Entry Delay N Disabled U Enabled
[4] Confidential Mode (not for UL installations) U Disabled N Enabled
[5] To exit Confidential Mode U
Enter code
N
Press Button
[6] Exit Delay Beep N Disabled U Enabled
[7]
Keypad Input Type
N Temp. input N Zone input
[8] Keypad Tamper U Disabled N Enabled
Section [003] Beep on Trouble
Options OFF ON
[1]
System & Clock Trouble Beep
U Disabled N Enabled
[2]
Communicator Trouble Beep
U Disabled N Enabled
[3]
Module & Combus Trouble Beep
U Disabled N Enabled
[4]
All Zone Trouble Beep
U Disabled N Enabled
[5] to [8]
Future Use
N N/A N N/A
Section
[004] Confidential Mode Timer
___/___/___ (005 to 255 seconds; Default: 120 seconds)
[005] Outside Temperature Calibration
___/___/___ (000 to 254; 000 and 128 = no calibration value)
[006] Inside Temperature Calibration
___/___/___ (000 to 254; 000 and 128 = no calibration value)
Komentarze do niniejszej Instrukcji