Modules Programming Guide - 41
EVO641/EVO641R Access Control Connections
LCD Keypad Module (EVO641/EVO641R) 48-Zone LED Keypad Module (DGP2-648)
Memory Key
Connector
To Digiplex
control panel
EVO48 or
EVO192
Please Note: The keypad’s
anti-tamper switch will
communicate its status to
the control panel via the
combus.
* The keypad’s zone
follows the control
panel’s EOL definition.
The zone speed is set at
600mS and cannot be
programmed.
Door Contact
Combus
To Digiplex
control panel
EVO48 or
EVO192
Please Note: The keypad’s
anti-tamper switch will
communicate its status to
the control panel via the
combus.
* The keypad’s zone
follows the control
panel’s EOL definition.
The zone speed is set at
600mS and cannot be
programmed.
Door Contact
Combus
EVO641R
EVO641R
Fused external power
supply (recommended)
Door Lock
IN4007
Diode
EVO641R
Paradoor (460)
Request to Exit device.
Must be connected to
Z2
terminal.
If a door contact is not being used, install a jumper
or a 1k
9
resistor across the BLK and Z1 terminals
depending on the control panel’s EOL definition.
If the REX (Request for Exit) device is not being
used, place a jumper across the BLK and Z2
terminals.
Door Contact
Must be connected
to
Z1 terminal.
* Follows control panel’s EOL definition.
No EOL
required for
Z2.