18 - Modules Programming Guide
APR3-ZX4 V1.0
4-zone Expansion Module
* For the Base Time, using Level Programming, press the and buttons to select a value from 000 to 002 and then press [ENTER]. Base Time Multipliers:
000 = 15 ms, 001 = 1 second, 002 = 1 minute.
U = Default setting
Section [001] General Options
Option OFF ON
[1] Tamper Recognition ON = Input 4 (Z4) becomes tamper input U Disabled N Enabled
[2] to [8] Future Use N N/A N N/A
Input Speed Base Time (000-002)* Time Value (000-255) Default
Input 001
[002] ___/___/___ [003] ___/___/___ 600ms
Input 002
[004] ___/___/___ [005] ___/___/___ 600ms
Input 003
[006] ___/___/___ [007] ___/___/___ 600ms
Input 004
[008] ___/___/___ [009] ___/___/___ 600ms
Input 005 (ATZ of Input 001)
[010] ___/___/___ [011] ___/___/___ 600ms
Input 006 (ATZ of Input 002)
[012] ___/___/___ [013] ___/___/___ 600ms
Input 007 (ATZ of Input 003)
[014] ___/___/___ [015] ___/___/___ 600ms
Input 008 (ATZ of Input 004)
[016] ___/___/___ [017] ___/___/___ 600ms