12 - Modules Programming Guide
DGP2-ANC1B V1.1
Annunciator Module
The DGP2-ANC1’s serial number is located on the module’s PC board.
U = Default Settings
Section [001] Partition Assignment
Options OFF ON
[1]
Partition 1
N Disabled U Enabled
[2]
Partition 2
N Disabled U Enabled
[3]
Partition 3
N Disabled U Enabled
[4]
Partition 4
N Disabled U Enabled
[5]
Partition 5
(EVO192 only) N Disabled U Enabled
[6]
Partition 6
(EVO192 only) N Disabled U Enabled
[7]
Partition 7
(EVO192 only) N Disabled U Enabled
[8]
Partition 8
(EVO192 only) N Disabled U Enabled
Section [002] General Options 1
Options OFF ON
[1]
Beeper Mute Mode
*
U Disabled N Enabled
[2]
Beep on System Trouble
U Disabled N Enabled
[3]
Beep on Communicator Trouble
U Disabled N Enabled
[4]
Beep on Combus/Module Trouble
U Disabled N Enabled
[5]
Zone Trouble
U Disabled N Enabled
[6] to [8]
Future Use
N N/A N N/A
*
In order for options
[2]
to
[5]
to function, option [
1]
must be disabled.
Sections Status Display Mode Description Default
[003] __/__/__ 000 Partition Status
000
__/__/__ 001 Zones 01 to 48
000
__/__/__ 002 Zones 49 to 96
000
__/__/__ 003 to 005 Future Use
n/a
Enter a value between 000 and 005 to set which status the Annunciator will display.