Module LED Indications
Green LOCATE LED (sometimes seen as LOC or LC):
Power Up: Remains illuminated during power up.
Locate: If the LED flashes fast during normal operation, it is receiving a
“locate” request from the control panel. Depending on the module, the
“locate” request can be disabled by pressing on the tamper switch or on
the “Disable Locate” switch.
Red WATCHDOG LED (sometimes seen as WDG, WTDG or WD):
Status: Flashes to indicate proper operation.
Communication Failure:
If both the LOCATE and WATCHDOG LEDs are alternately flashing, the
module is experiencing a communication failure with the control panel.
Green BATT LED (DGP2-ACM1P and DGP2-PS17 only):
Charging and battery test LED (every 60 seconds).
Green RX LED (MG-RTX3 only):
Flashing: The printer module is transmitting data through the serial port.
Green PULSE LED (APR-ADM2 only):
Will illuminate whenever the APR3-ADM2 is using its dialer. The PULSE
LED will remain illuminated for the whole duration that the dialer is being
used.
Remove AC and battery power from the control panel before
connecting the module to the combus.
Refer to the appropriate control panel’s Reference & Installation
Manual for the maximum allowable installation distance from the
control panel.
Any device such as a garage
door, light or siren.
External Power
Supply
PGM 5A
Relay
Figure 2: Connecting a 5A PGM Output
Some modules’ PGM output(s) are comprised of
one or more 5A relays. Connect the PGM output as
shown below. For the external power supply, we
recommend the DGP2-PS17 Power Supply Module.
Figure 3: Connecting a 50mA PGM Output
Some modules’ PGM output is comprised of one 50mA
output. Connect the PGM output as shown below.
Figure 1: Connecting the Combus
Digiplex control panel
(EVO48 & EVO192)
Combus
Module
Module
Open Collector
(Negative Trigger)
12 Vdc 50 mA
To drive more than
50mA
use a 12Vdc relay