Digiplex -EVO- - 63 - Programming Guide
Telephone Line Connections
Table 5: Milliamp Consumption Table
STEP 1: Using Table 5, calculate the total number of milliamps (mA) required by each device, module, and accessory in the system. Please take into
account devices connected to the control panel’s PGM outputs. Since the
BELL output has its own power supply, do not include the sirens
connected to it in the calculation.
Description QTY. mA used by each Total mA
Grafica Graphic LCD Keypads (DNE-K07): _______ X 130mA = __________ mA
LCD Keypads (EVO641): _______ X 110mA = __________ mA
LCD Keypads with Built-in Reader (EVO641R): _______ X 120mA = __________ mA
LED Keypads (DGP2-648): _______ X 110mA = __________ mA
Motion Detector Modules (DG85, DGP2-50/60/70): _______ X 30mA = __________ mA
Door Contact Modules (DGP2-ZC1): _______ X 15mA = __________ mA
1-Zone Expansion Modules (DGP2-ZX1): _______ X 30mA = __________ mA
4-Zone Expansion Modules (APR3-ZX4): _______ X 30mA = __________ mA
8-Zone Expansion Modules (APR-ZX8): _______ X 30mA = __________ mA
Magellan Wireless Expansion Modules (MG-RTX3): _______ X 35mA = __________ mA
4-PGM Expansion Modules (APR3-PGM4): _______ X 150mA = __________ mA
Printer Modules (APR-PRT3): _______ X 25mA = __________ mA
DVACS Modules (DGP2-DVAC): _______ X 40mA = __________ mA
Annunciator Modules (DGP2-ANC1): _______ X 20mA = __________ mA
InTouch Voice-Assisted Arm/Disarm Modules (APR3-ADM2): _______ X 105mA = __________ mA
Hub and Bus Isolator (APR3-HUB2): _______ X 50mA = __________ mA
Access Control Module (DGP-ACM12):
Note: The DGP-ACM12 consumes 130mA from its own power supply or 120mA
when connected on the combus for power.
_______ X 120mA = __________ mA
Listen-In Module (DGP-LSN4) _______ X 60mA = __________ mA
Internet Module (IP100) _______ X 110mA = __________ mA
Plug-In Voice Module (VDMP3) _______ X 35mA = __________ mA
Other devices such as hardwired motion detectors __________ mA
Maximum available milliamps = 700mA GRAND TOTAL __________ mA
For TBR-21 compliance, please note the following:
1) The EVO panel can be connected to the telephone network via an RJ-11 connector.
2) The Maximum Dialing Attempts cannot exceed 15 attempts (section [3056] on page 39).