Digiplex -EVO- - 37 - Programming Guide
= Default setting
*This option is used by some event monitoring software such as Hyperterminal. With WinLoad and printers, it is always being transmitted,
*For instructions on wiring a panel for tamper recognition, see page 61.
SECTION [3031] : Partition Options 1 SECTION [3032] : Partition Options 2
Option
OFF ON
Option
OFF ON
[1] Partition 1 N Disabled
Enabled
[1] Bell/siren output in partition 1 N Disabled
Enabled
[2] Partition 2
Disabled
N Enabled [2] Bell/siren output in partition 2
Disabled
N Enabled
[3] Partition 3
Disabled
N Enabled [3] Bell/siren output in partition 3
Disabled
N Enabled
[4] Partition 4
Disabled
N Enabled [4] Bell/siren output in partition 4
Disabled
N Enabled
[5] Partition 5 (EVO192 only)
Disabled
N Enabled [5]
Bell/siren output in partition 5
Disabled
N Enabled
[6] Partition 6 (EVO192 only)
Disabled
N Enabled [6] Bell/siren output in partition 6
Disabled
N Enabled
[7] Partition 7 (EVO192 only)
Disabled
N Enabled [7] Bell/siren output in partition 7
Disabled
N Enabled
[8] Partition 8 (EVO192 only)
Disabled
N Enabled [8] Bell/siren output in partition 8
Disabled
N Enabled
SECTION [3033] : System Options 3 SECTION [3034] : System Options 4
Option
OFF ON
Option
OFF ON
[1] Multiple actions in user menu
Disabled
N Enabled
[1]&[2] Wireless Transmitter Supervision
Options (see Table on page 37)
N
See Table
N
See Table
N
See Table
N
See Table
[2] User code length
Fixed
N Flexible
[3] User code length (if option [2] OFF)
4-digits
N 6-digits
[3]
Generate supervision failure if
detected on a bypassed wireless zone
Yes
N No
[4] Power save mode N Disabled
Enabled
[4] Restrict arming on a wireless
transmitter supervision failure
Disabled
N Enabled
[5]
Bypass not displayed while system
is armed
N Disabled
Enabled
[5]&[6] Zone & Module Tamper Recognition
Options (see Table on page 37)
N
See Table
N
See Table
N
See Table
N
See Table
[6] Trouble Latch
Disabled
N Enabled
[7] EOL resistor on hardwire zones
Disabled
N Enabled
[7] Generate tamper if detected on
bypass zone
NYes
No
[8] (ATZ) Zone Doubling
Disabled
N Enabled
[8]
Restrict arming on tamper trouble
Disabled
N Enabled
SECTION [3035] : System Options 5
Option
OFF ON
[1] Restrict arming on AC failure
Disabled
N Enabled
[2]
Restrict arming on battery failure
Disabled
N Enabled
[3] Restrict arming on bell or auxiliary
failure
Disabled
N Enabled
[4] Restrict arming on TLM failure
Disabled
N Enabled
[5] Restrict arming on module
troubles
Disabled
N Enabled
[6] Account Number Transmission
Partition #
N Tel #
[7] Transmit zone status on serial
port*
Disabled
N Enabled
[8] Serial Port Baud Rate N38,400
57,600
Wireless Transmitter Supervision Options
(Section [3034]; options [1] & [2])
Zone & Module Tamper Recognition Options*
(Section [3034]: options [5] & [6])
[1] [2] [5] [6]
OFF OFF - Disabled (default) OFF OFF - Disabled (default)
OFF ON -
GENERATES TROUBLE ONLY (WHEN ARMED OR DISARMED)OFFON- GENERATES TROUBLE ONLY (WHEN ARMED OR DISARMED)
ON OFF - When disarmed:
GENERATES TROUBLE ONLY ON OFF - When disarmed: GENERATES TROUBLE ONLY
- When armed: Follows Zone Alarm Types (page 9)
- When armed: Follows Zone Alarm Types (page 9) for Zone
Tamper. Generates Trouble for Module Tamper.
ON ON - When disarmed:
GENERATES AUDIBLE ALARM ON ON - When disarmed: GENERATES AUDIBLE ALARM
- When armed: Follows Zone Alarm Types (page 9) - When armed: Follows Zone Alarm Types (page 9)