Digiplex -EVO- - 51 - Programming Guide
Installer Function Keys
To access the installer functions, press and hold the [0] key, enter the [INSTALLER CODE], and then:
For LCD keypads: press the key indicated in the list below that corresponds to the function you wish to activate.
For Grafica keypads: press the center action key (Options), highlight the desired function and then press the center action key (Ok).
Automatic Report Code List
Section Description
[4040] Entering this section will reset all programmable sections from [0001] to [3999] to factory default values.
[4041] Entering this section will reset the system master code to 123456.
[4042] Entering this section will reset all Zone programming (including sections [0961] to [0984]) programming to default values.
[4043] Entering this section will reset all access control sections from [2201] to [2712], excluding door labels, to default values.
[4044] Entering this section will reset all user code sections from [1001] to [1999] and [2001] to [2199] to default values.
[4045] Entering this section will reset all dialer (sections [3051] to [3081]), VDMP3 (sections [3087] to [3098]) and control panel (sections [3020] to
[3043], and [3900] to [3991]) programming to default values.
[4046] Entering this section will reset all partition sections from [3101] to [3833], excluding partition labels, to default values.
[4047] Entering this section will reset all PGM (sections from [0901] to [0959]) and all Keyswitch (sections [0501] to [0632]) programming, as well
as all Keyswitch arming/disarming report codes (sections from [0701] to [0832]) to default values.
[4048] Entering this section will clear all user labels, door labels, partition labels, module labels and zone labels from sections [0301] to [0396].
[4049] Entering this section will unlock software reset for sections [4040] to [4048].
[
STAY] Test Report: Sends the “Test Report” report code programmed in section [3902] to the monitoring station.
[
FORCE]
Call WinLoad Software: Will dial the PC telephone number programmed in section [3010] in order to initiate communication with a computer
using the WinLoad software.
[
ARM] Answer WinLoad Software: Will force the control panel to answer a call made by the Monitoring Station that is using the WinLoad software.
[
DISARM] Cancel Communication: Cancels all communication with the WinLoad software or with the Monitoring Station until the next reportable event.
[
MEM]
Installer Test Mode: The installer test mode will allow you to perform walk tests where the bell or siren will squawk to indicate opened zones.
Press the [
MEM] button again to exit. Partitions cannot be armed if the Installer Test Mode is enabled.
[
TRBL] Start Module Scan: The keypad will display the serial number of each module on the combus.
[
ACC] Combus Voltmeter: To verify if the combus is supplying sufficient power, press and hold the [0] key, enter the [INSTALLER CODE] and press the
[
ACC] button. A reading of 12.3V or lower at the panel’s service keypad connector indicates that the voltage is too low. The voltage may drop
during the control panel battery test.
System Event
Default Contact ID Report Code
when using sections [4032] to [4037]
Default SIA Report Code
when using sections [4032] to [4037]
Arming with Master Code (##) 3 4A1 - Close by user CL - Closing Report
Arming with User Code (##) 3 4A1 - Close by user CL - Closing Report
Arming with Keyswitch (##) 3 4A9 - Keyswitch Close CS - Closing Keyswitch
Auto Arming 3 4A3 - Automatic Close CA - Automatic Closing
Arm with PC software 3 4A7 - Remote arm/disarm CQ - Remote Arming
Late To Close 3 452 - Late to Close OT - Late to Close
No Movement 3 452 - Late to Close NA - No Movement Arming
Partial arming 1 456 - Partial Arm CG - Close Area
Quick arming 3 4A8 - Quick arm CL - Closing Report
Remote Arm (voice) 3 4A7 - Remote Arm CQ - Arm with Voice Module
Delinquency Closing 1 654 - System Inactivity CD - System Inactivity
Disarm with Master Code (##) 1 4A1 - Open by user OP - Opening Report
Disarm with User Code (##) 1 4A1 - Open by user OP - Opening Report
Disarm with Keyswitch (##) 1 4A9 - Keyswitch Open OS - Opening Keyswitch
Disarm after alarm with Master Code (##) 1 4A1 - Open by user OP - Opening Report
Disarm after alarm with User Code (##) 1 4A1 - Open by user OP - Opening Report
Disarm after alarm with Keyswitch (##) 1 4A9 - Keyswitch Open OS - Opening Keyswitch
Cancel alarm with Master Code (##) 1 4A6 - Cancel OR - Disarm From Alarm
Cancel alarm with User Code (##) 1 4A6 - Cancel OR - Disarm From Alarm
Cancel alarm with Keyswitch (##) 1 4A6 - Cancel OS - Opening Keyswitch
Auto Arming Cancellation 1 464 - Auto-Arm Time Extended CE - Closing Extend