Digiplex -EVO- - 38 - Programming Guide
Dialer Options
= Default setting
Other Options
SECTION [3036]: Dialer Options 1 SECTION [3037] : Dialer Options 2
Option
OFF ON
Option
OFF ON
[1]&[2]
Telephone Line Monitoring (TLM) -
(see table below)
N
See Table
N
See Table
N
See Table
N
See Table
[1] Call back
Disabled
N Enabled
[2] Automatic event buffer transmission
Disabled
N Enabled
[3] Dialer (reporting to monitoring
station)
Disabled
NEnabled [3]&[4] Auto Test Report Transmission
Options (see Auto Test Report
Settings on page 38)
N
See Table
N
See Table
N
See Table
N
See Table
[4] Dialing method
N Pulse
Tone
(DTMF)
[5]
Pulse ratio
(E.U. = Europe; N.A. = North America)
N 1:2 (E.U.)
1:1.5
(N.A.)
[5] Keypad beep on successful arming/
disarming report
Disabled
N Enabled
[6] Busy tone detection N Disabled
Enabled
[6] Alternate Dialing
Disabled
N Enabled
[7]
Switch to pulse dialing on 5
th
attempt
Disabled
N Enabled [7] Dial Tone Delay (if no dial tone)
Force dial
N Hang-up
[8]
Bell/siren upon communication
failure if system is armed
Disabled
N Enabled [8] Report zone restore
ON = On zone closure; OFF = On bell cut-off
Disabled
N Enabled
Telephone Line Monitoring (TLM) Options
(Section [3036]; options [1] & [2])
Auto-Test Report Transmission Options
(Section [3037]; options [3] & [4])
[1] [2] [3] [4]
OFF
OFF
ON
ON
OFF
ON
OFF
ON
Disabled (default)
When armed:
GENERATES AN AUDIBLE ALARM
When armed: GENERATES A TROUBLE
TLM silent alarm:
BECOMES AN AUDIBLE ALARM
OFF OFF Transmit the test report code every time the days programmed
in section [3040] have elapsed at the time programmed in
section [3041] (default).
OFF ON When disarmed: Transmit test report code every time the
time programmed in section [3043] has elapsed.
When armed: Transmit test report code every time the time
programmed in section [3042] has elapsed.
ON OFF The control panel will transmit the test report code every hour
on the minute value programmed in section [3041] (the last
two digits). Note that the first two digits of section [3041] will
be ignored. For example, if 10:25 was programmed into
section [3041], the test report code would be transmitted at
the 25
th
minute of every hour, i.e. 11:25, 12:25, etc.
ON ON The test report code will be transmitted when any of the
conditions of the second and third options listed above
(options [3] = OFF and [4] = ON / options [3] = ON and [4] =
OFF) are met.
= Default setting
SECTION [3038]: Access Control Options
Option
OFF ON
[1] Access control feature
Disabled
N Enabled
[2]
Log “Request for Exit” in event
buffer*
Disabled
N Enabled
[3]
Log “Door Left Open Restore” in
event buffer
Disabled
N Enabled
[4]
Log “Door Forced Restore” in event
buffer
Disabled
N Enabled
[5]
Burglar alarm on forced door
Disabled
N Enabled
[6]
Skip exit delay when arming with
access card
Disabled
N Enabled
[7] Burglar alarm on door left open
Disabled
N Enabled
[8] Who has access during clock loss
All users
N Masters*
* Since “Request for Exit” events can occur often, the Event
Buffer may fill up quickly.
* This also includes users with 00 for schedule access.