Digiplex -EVO- - 54 - Programming Guide
SYSTEM TROUBLES - 300 & 310 378 Cross-Zone Trouble 6D 458 User on Premises A1
300 System Trouble 39 SENSOR TROUBLES - 380 459 Recent Close A2
301 AC Loss 3A 380 Sensor Trouble 6E 461 Wrong Code Entry A3
302 Low System Battery 3B 381 Loss of Supervision - RF 6F 462 Legal Code Entry A4
303 RAM Checksum Bad 3C 382 Loss of Supervision - RPM 70 463 Re-arm after Alarm A5
304 ROM Checksum Bad 3D 383 Sensor Tamper 71 464 Auto-Arm Time Extended A6
305 System Reset 3E 384 RF Transmitter Low Battery 72 465 Panic Alarm Reset A7
306 Panel Program Changed 3F 385 Smoke Detector Hi Sensitivity 73 466 Service On/Off Premises A8
307 Self-Test Failure 40 386 Smoke Detector Low Sensitivity 74 SOUNDER RELAY DISABLES - 520
308 System Shutdown 41 387 Intrusion Detector Hi Sensitivity 75 520 Sounder/Relay Disabled A9
309 Battery Test Failure 42 388 Intrusion Detector Low Sensitivity 76 521 Bell 1 Disable AA
310 Ground Fault 43 389 Sensor Self-Test Failure 77 522 Bell 2 Disable AB
311 Battery Missing/Dead 44 391 Sensor Watch Trouble 78 523 Alarm Relay Disable AC
312 Power Supply Over Current 45 392 Drift Compensation Error 79 524 Trouble Relay Disable AD
313 Engineer Reset 46 393 Maintenance Alert 7A 525 Reversing Relay Disable AE
SOUNDER/RELAY TROUBLES - 320 OPEN/CLOSE - 400 526
Notification Appliance chk. #3
Disabled
AF
320 Sounder Relay 47 400 Open/Close 7B 527
Notification Appliance chk. #4
Disabled
B0
321 Bell 1 48 401 Open/Close by User 7C 531 Module Added B1
322 Bell 2 49 402 Group Open/Close 7D 532 Module Removed B2
323 Alarm Relay 4A 403 Automatic Open/Close 7E COMMUNICATION DISABLED - 550 & 560
324 Trouble Relay 4B 406 Cancel 7F 551 Dialer Disabled B3
325 Reversing Relay 4C 407 Remote Arm/Disarm 80 552 Radio Transmitter Disabled B4
326 Notification Appliance chk. #3 4D 408 Quick Arm 81 BYPASSES - 570
327 Notification Appliance chk. #4 4E 409 Keyswitch Open/Close 82 570 Zone Bypass B5
SYSTEM PERIPHERAL TROUBLES - 330 & 340 REMOTE ACCESS - 410 571 Fire Bypass B6
330 System Peripheral 4F 411 Callback Request Made 83 572 24-Hour Zone Bypass B7
331 Polling Loop Open 50 412 Successful - Download Access 84 573 Burglary Bypass B8
332 Polling Loop Short 51 413 Unsuccessful Access 85 574 Group Bypass B9
333 Expansion Module Failure 52 414 System Shutdown 86 575 Swinger Bypass BA
334 Repeater Failure 53 415 Dialer Shutdown 87 576 Access Zone Shunt BB
335 Local Printer Paper Out 54 416 Successful Upload 88 577 Access Point Bypass BC
336 Local Printer Failure 55 ACCESS CONTROL - 420 TEST/MISC. - 600
337 Exp. Module DC Low 56 421 Access Denied 89 601 Manual Trigger Test BD
338 Exp. Module Low Batt 57 422 Access Report By User 8A 602 Periodic Test Report BE
339 Exp. Module Reset 58 423 Forced Access 8B 603 Periodic RF Transmission BF
341 Exp. Module Tamper 59 424 Egress Denied 8C 604 Fire Test C0
342 Exp. Module AC Lost 5A 425 Egress Granted 8D 605 Status Report to Follow C1
343 Exp. Module Self-Test Fail 5B 426 Access Door Propped Open 8E 606 Listen-in to Follow C2
344 RF Receiver Jam Detected 5C 427
Access Point Door Status Monitor
trouble
8F 607 Walk Test Mode C3
COMMUNICATION TROUBLES - 350 & 360 428 Access Point Request to Exit 90 608
Periodic Test - System Trouble
Present
C4
350 Communication 5D 429 Access Program Mode Entry 91 609 Video Xmitter Active C5
351 Telco Fault 1 5E 430 Access Program Mode Exit 92 611 Point Test Ok C6
352 Telco Fault 2 5F 431 Access Threat Level Change 93 612 Point Not Tested C7
353 Long Range Radio 60 432 Access Relay/Trigger Fail 94 613 Intrusion Zone Walk Tested C8
354 Fail to Communicate 61 433 Access RTE Shunt 95 614 Fire Zone Walk Tested C9
355 Loss of Radio Supervision 62 434 Access DSM Shunt 96 615 Panic Zone Walk Tested CA
356 Loss of Central Polling 63 441 Armed Stay 97 616 Service Request CB
357 Long Range Radio VSWR problem 64 442 Keyswitch Armed Stay 98 621 Event Log Reset CC
PROTECTION LOOP TROUBLES - 370 SPECIAL TROUBLES - 450 & 460 622 Event Log 50% Full CD
370 Protection Loop 65 450 Exception Open/Close 99 623 Event Log 90% Full CE
371 Protection Loop Open 66 451 Early Open/Close 9A 624 Event Log Overflow CF
372 Protection Loop short 67 452 Late Open/Close 9B 625 Time/Date Reset D0
373 Fire Trouble 68 453 Failed to Open 9C 626 Time/Date Inaccurate D1
374 Exit Error Alarm 69 454 Failed to Close 9D 627 Program Mode Entry D2
375 Panic Zone Trouble 6A 455 Auto-Arm Failed 9E 628 Program Mode Exit D3
376 Hold-up Zone Trouble 6B 456 Partial Arm 9F 629 32 Hour Event Log Marker D4
377 Swinger Trouble 6C 457 User Exit Error A0 630 Schedule Change D5
CID# Reporting Code
Prog.
Value
CID# Reporting Code
Prog.
Value
CID# Reporting Code
Prog.
Value