36 Reference & Installation Manual
12.4 Installer Code Lock
SECTION [990]
Enter 147 into section [990] to lock all programming. When 147 is
programmed in section [990], performing a hardware reset as
described in section 12.1 on page 35 will not affect the current
panel settings. To remove the Installer Lock, enter 000 into section
[990]. (Default: Unlocked)
12.5 Partitioning
SECTION [500]: OPTIONS [1] TO [4]
The Digiplex control panel can provide your system with up to four
completely independent partitions. Most features and options in the
Digiplex System can be independently set for each partition such
as Event Reporting, Entry/Exit Delay, Bell Squawk, One-Touch
arming, Panic Alarms and many more. All zones, keyswitch zones,
user codes and system modules are assigned to specific partitions,
making this a true partitioned system. In section [500], enable the
option(s) that correspond to the desired partition(s). Where options
[1] to [4] represent partitions 1 through 4.
12.5.1 Panel Partition Assignment
SECTION [440]
The control panel will report system events as originating from the
partitions enabled in this section. The System Troubles (i.e. AC
Failure, TLM Failure, etc.) can only be viewed through the
partitions enabled in this section.
00 = All enabled partitions (see section [500])
01 = Control panel installed in Partition 1
02 = Control panel installed in Partition 2
03 = Control panel installed in Partition 3
04 = Control panel installed in Partition 4
12.6 Installer Function Keys
To access the installer functions, press and hold the [0] key, enter
the [INSTALLER CODE], and then...
For LCD keypads: press the key indicated in the list below that
corresponds to the function you wish to activate.
For Grafica keypads: press the center action key (Options),
highlight the desired function and then press the center action key
(Ok).
Test Report: [STAY]
Sends the Test Report report code programmed in section [717] to
the monitoring station.
Call WinLoad: [FORCE]
Will dial the PC telephone number programmed in section [560] to
communicate with a computer using WinLoad.
Answer WinLoad: [ARM]
Will force the control panel to answer a call made by the monitoring
station that is using WinLoad.
Cancel Communication: [DISARM]
Pressing this function key cancels all communication with the
monitoring station or WinLoad until the next reportable event.
Installer Test Mode: [MEM]
The Installer Test Mode will allow you to perform walk tests where
the bell or siren will squawk to indicate opened zones. Press [MEM]
again to exit. Partitions cannot be armed if the Installer Test Mode
is enabled.
Module Scan: [TRBL]
This feature instructs the control panel to verify the status of the
modules connected to the combus. The control panel will fix any
problems with the internal organization of the modules in the
control panel. The keypads will display the serial number of each
module that has been connected to the combus.
Combus Voltmeter: [ACC]
LCD keypads (DGP2-641BL) only.
To verify if the combus is supplying sufficient power, press and hold
the [0] key, enter the [
INSTALLER CODE] and press the [ACC] key on
the LCD keypad. A reading of 9.2V indicates that the voltage is too
low. The voltage may drop during the control panel battery test (see
section 2.4.1 on page 2).
12.7 System Date & Time
SECTION [502]: OPTION [6]
The System Date and Time is programmed through the User
Menu, please refer to Clock Loss in section 16.7 on page 47.
12.7.1 Daylight Savings Time
By enabling option [6] in section [502], the control panel will
automatically adjust the system's clock (time) for daylight saving
changes. At 2:00AM on the first Sunday of a full weekend in April,
the control panel will add one hour to the programmed time (clock).
At 2:00AM on the last Sunday of a full weekend in October, the
control panel will subtract one hour from the programmed time
(clock).
12.8 Shabbat Feature
SECTION [522]: OPTION [4]
With option [4] on, all addressable detection devices and keypads
in the system will no longer display any system status through the
LCD and/or LEDs between noon (12:00PM) Friday and midnight
(12:00AM) Saturday. Therefore, normal operation will be re-
instated Sunday morning at 12:00:01AM.
During the Shabbat period:
• the LCD keypads only display the date and time
• the backlight is disabled
• the LED indicators on all addressable detection devices and
keypads in the system are disabled
If required, a user can access all the usual commands and features
during the Shabbat period by pressing a key or, if Confidential
Mode is enabled in the keypad, by entering their access code.
When no actions have occurred for two minutes, the Shabbat
Feature will re-activate.
12.9 Module Reset
SECTION [951]
To reset a module that is connected to the combus to its default
values, key in the module's serial number into section [951].
12.10 Locate Module
SECTION [952]
If you wish to locate a specific module (e.g. detector, zone
expansion module, etc.) connected to the combus, key in the
module's serial number into section [952]. The green
LOCATE LED