Digiplex DGP2-641BL Instrukcja Instalacji Strona 30

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 48
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 29
30 - Digiplex Modules Programming Guide
Module Connection Drawings
Module Connection Overview
Module LED Indications
Green LOCATE LED (sometimes seen as LOC or LC):
Power Up: Remains illuminated during power up.
Locate: If the LED flashes fast during normal operation, it is receiving a “locate”
request from the control panel. Depending on the module, the “locate” request can
be disabled by pressing on the tamper switch or on the “Disable Locate” switch.
Red WATCHDOG LED (sometimes seen as WDG, WTDG or WD):
Status: Flashes to indicate proper operation.
Communication Failure:
If both the LOCATE and WATCHDOG LEDs are alternately flashing, the module is
experiencing a communication failure with the control panel.
Green BATT LED (DGP2-ACM1P and DGP2-PS17 only):
Charging and battery test LED (every 60 seconds).
Green RX LED (MG-RCV3 only):
Flashing: The printer module is transmitting data through the serial port.
Green PULSE LED (APR-ADM2 only):
Will illuminate whenever the APR3-ADM2 is using its dialer. The PULSE LED will
remain illuminated for the whole duration that the dialer is being used.
General Warnings
Remove AC and battery power from the control panel before
connecting the module to the combus.
Refer to the appropriate control panel’s Reference & Installation
Manual for the maximum allowable installation distance from the
control panel.
Any device such as a garage
door, light or siren.
External Power
Supply
PGM
5A
Relay
Figure 2: Connecting a 5A PGM Output
Some modules’ PGM output(s) are comprised of one or
more 5A relays. Connect the PGM output as shown below.
For the external power supply, we recommend the DGP2-
PS17 Power Supply Module.
Figure 3: Connecting a 50mA PGM Output
Some modules’ PGM output is comprised of one 50mA output.
Connect the PGM output as shown below.
Figure 1: Connecting the Combus
Digiplex control panel
(DGP-848/DGP-NE96)
Combus
Module
Module
Przeglądanie stron 29