Digiplex Modules Programming Guide - 17
1-PGM Expansion Module
U = Default setting
Refer to Appendix 1: Programming PGMs on page 41 for the PGM Table. All the Event Groups can be used to program the module’s PGM.
SECTION [001] : General Options SECTION [002] : PGM Options
Option OFF ON Option OFF ON
[1] Future Use N N/A N N/A [1] PGM Deactivation After
U
Deactiva-
tion Event
N
PGM Timer
[2] Pulse Output for Fire Alarms
U Disabled
N Enabled [2] PGM Base Time
U 1 second
N 1 minute
[3] to [8] Future Use N N/A N N/A [3] to [8] Future Use N N/A N N/A
Section Data Description Default
[003] __/__/__ (000 to 255; see option [2] in section [002])PGM Timer 005
Event Group Feature Group Start # End #
Section Section Section Section
PGM Activation [004] __/__/__ [005] __/__/__ [006] __/__/__ [007] __/__/__
PGM Deactivation [008] __/__/__ [009] __/__/__ [010] __/__/__ [011] __/__/__
APR3-PGM1 V2.0