20 - Digiplex Modules Programming Guide
1-zone Expansion Module
INPUT SPEED = BASE TIME x TIME VALUE (Default: 600mS)
U = Default setting
SECTION [001] : General Options
Option OFF ON
[1] Tamper Recognition
U Disabled
N Enabled
[2] to [8] Future Use N N/A N N/A
Base Time (000 to 002)*
SECTION Data
[002]
___/___/___
*For the Base Time, using Level Programming (refer to page 1), press the and buttons to select a value from 000 to 002 and then press
[
ENTER]. Base Time Multipliers: 000 = 15 ms, 001 = 1 second, 002 = 1 minute.
Time Value (001 to 255)
SECTION Data
[003]
___/___/___
DGP2-ZX1 V2.0