Digiplex LCD Keypad 13n
The intermittent beep will be re-initialized whenever the trouble
condition re-occurs.
Option [1] OFF
= Beep disabled: System Troubles and Clock Loss (default)
Option [1] ON = Beep enabled: System Troubles and Clock Loss
Option [2] OFF = Beep disabled: Communicator Troubles (default)
Option [2] ON = Beep enabled: Communicator Troubles
Option [3] OFF = Beep disabled: Module and Bus Troubles (default)
Option [3] ON = Beep enabled: Module and Bus Troubles
Option [4] OFF = Beep disabled: all Zone Troubles (default)
Option [4] ON = Beep enabled: all Zone Troubles
4.10 KEYPAD TAMPER ENABLE
Section 005: Option [5]
When Tamper is enabled and the keypad's on-board tamper switch
is triggered, the keypad will send a Tamper report to the control
panel via the communication bus.
Option [5] OFF = Keypad's Tamper is disabled (default)
Option [5] ON = Keypad's Tamper is enabled