Digiplex Access Control 19
3.2.3 “Door Forced Open” Alarm
If an Access Control Door is opened without an Access Control
Card, a User Access Code, or receiving a “Request for Exit” from
the motion detector, an alarm can be generated. When this alarm
is audible, it will emit a rapid beep.
When the door is closed during the alarm, the “Door Forced
Restore” event can be logged in the Event Record Display (see
Event Record Display in the Digiplex LCD Keypad User’s
Manual). The “Door Forced Open” Alarm can also generate a
Burglar Alarm, which can be reported to the Security Company.
3.3 ARMING AND DISARMING
3.3.4 Arming with Card
An Access Control Card can be programmed to arm area(s)
assigned to the door when a it is presented to the reader twice
within approximately 5 seconds without opening the door.
The Access Control card must be:
• presented during its assigned Schedule
• presented within its assigned Access Level
• programmed to allow arming (see section 2.1.2, p. 9)
• assigned to all areas that are assigned to the Access Control
door. For example, if the door is assigned to areas 1 and 4,
an Access Control card assigned to area 4 will not work.